Availability: | |
---|---|
Quantity: | |
CPF-1000D2
Waterman
Disinfection
ISO
1 Year
Disinfection Machine
Chemical Treatment
Industrial
Plywood Box
0-2000 gr/hr
Manual / Residual CLO2 control
Tap water, cooling water, process water, waste water, etc.
380V / 50Hz
injection, spraying
Auto
Sodium chlorite and Hydrochlorite acid, or other options
Skid mounted
PVC
2000 g/h
China
Raw chemical preparation and storage system, raw chemical delivery, generator reaction system and dosing system, control and security system.
Skid-mounted + combination (see figure below for reference only).
The generator host is skid-mounted: with metering pumps, flow meters, reactor & shell, control system.
The raw chemical dissolving & storage systems are combined.
NaCLO2+HCL→CLO2+NaCL+H2O
NaCLO3+H2O2+H2SO4→CLO2+Na2SO4+O2+H2O (H2O2 is optional)
Raw chemicals of salt and acid are pumped into the reactor synchronously by two metering pumps at supplier's prescribed proportion, mixed and reacted to generate purity concentrated CLO2, and then directly added to the water for applicaiton of disinfection, algae removal, bleaching, deodorization, etc.
In the online automatic control mode, the generator adjusts the working frequency of the metering pump online by receiving the 4-20mA signal to control the ClO2 generation.
The NaCLO3 (solid)+H2O2 mixture is dissolved by the dissolving tank with manual start/stop control, after dissolution is completed, it is pumped into NaCLO3 storage tank by circulation pump.
The HCL and H2SO4 is pumped into the storage tank by an unloading pump.
Main parameters:
Working temperature: 5 ~ 40 degrees Celsius
Operating voltage: 220V plus or minus 10% / 380V plus or minus 10%
Operating current:<5A
There should be no strong electric field and magnetic field interference around equipment.
Maximum pressure of water-pipe-line:<0.7Mpa
Functions: Flow-on-line control, or manual control
Low liquid level alarm of raw materials
Timing and linkage with water pump
Model | ClO2 Capacity (g/h) | Disinfection capacity | Host package dimensions (mm) | |||
Drinking water (ton) | Medical wastewater (ton) | Swimming pool water (ton) | Cooling water (ton) | |||
CPF-50D1/D2 | 0~50 | 50~100 | 2.5~5 | 25~50 | 25~150 | 1400×470×1550 |
CPF-200D1/D2 | 0~200 | 200~400 | 10~20 | 100~200 | 100~600 | 1500×470×1620 |
CPF-500D1/D2 | 0~500 | 500~1000 | 25~50 | 250~500 | 250~1500 | 1800×550×1620 |
CPF-1000D1/D2 | 0~1000 | 1000~2000 | 50~100 | 500~1000 | 500~3000 | 2400×1400×2100 |
CPF-5000D1/D2 | 0~5000 | 5000~10000 | 250~500 | 2500~5000 | 2500~15000 | 2400×1400×2100 |
CPF-10000D1/D2 | 0~10000 | 10000~20000 | 500~1000 | 5000~10000 | 5000~30000 | 2400×1400×2100 |
CPF-20000D1/D2 | 0~10000 | 10000~20000 | 500~1000 | 5000~10000 | 5000~30000 | 2400×1400×2100 |
Raw chemical preparation and storage system, raw chemical delivery, generator reaction system and dosing system, control and security system.
Skid-mounted + combination (see figure below for reference only).
The generator host is skid-mounted: with metering pumps, flow meters, reactor & shell, control system.
The raw chemical dissolving & storage systems are combined.
NaCLO2+HCL→CLO2+NaCL+H2O
NaCLO3+H2O2+H2SO4→CLO2+Na2SO4+O2+H2O (H2O2 is optional)
Raw chemicals of salt and acid are pumped into the reactor synchronously by two metering pumps at supplier's prescribed proportion, mixed and reacted to generate purity concentrated CLO2, and then directly added to the water for applicaiton of disinfection, algae removal, bleaching, deodorization, etc.
In the online automatic control mode, the generator adjusts the working frequency of the metering pump online by receiving the 4-20mA signal to control the ClO2 generation.
The NaCLO3 (solid)+H2O2 mixture is dissolved by the dissolving tank with manual start/stop control, after dissolution is completed, it is pumped into NaCLO3 storage tank by circulation pump.
The HCL and H2SO4 is pumped into the storage tank by an unloading pump.
Main parameters:
Working temperature: 5 ~ 40 degrees Celsius
Operating voltage: 220V plus or minus 10% / 380V plus or minus 10%
Operating current:<5A
There should be no strong electric field and magnetic field interference around equipment.
Maximum pressure of water-pipe-line:<0.7Mpa
Functions: Flow-on-line control, or manual control
Low liquid level alarm of raw materials
Timing and linkage with water pump
Model | ClO2 Capacity (g/h) | Disinfection capacity | Host package dimensions (mm) | |||
Drinking water (ton) | Medical wastewater (ton) | Swimming pool water (ton) | Cooling water (ton) | |||
CPF-50D1/D2 | 0~50 | 50~100 | 2.5~5 | 25~50 | 25~150 | 1400×470×1550 |
CPF-200D1/D2 | 0~200 | 200~400 | 10~20 | 100~200 | 100~600 | 1500×470×1620 |
CPF-500D1/D2 | 0~500 | 500~1000 | 25~50 | 250~500 | 250~1500 | 1800×550×1620 |
CPF-1000D1/D2 | 0~1000 | 1000~2000 | 50~100 | 500~1000 | 500~3000 | 2400×1400×2100 |
CPF-5000D1/D2 | 0~5000 | 5000~10000 | 250~500 | 2500~5000 | 2500~15000 | 2400×1400×2100 |
CPF-10000D1/D2 | 0~10000 | 10000~20000 | 500~1000 | 5000~10000 | 5000~30000 | 2400×1400×2100 |
CPF-20000D1/D2 | 0~10000 | 10000~20000 | 500~1000 | 5000~10000 | 5000~30000 | 2400×1400×2100 |